古诗大全300首小学,一杆大枪草一家三娘的故事,男人的坤坤升到女人的坤坤,国产处破苞无码精品网站下载

首頁 > 粉體測試設備 > 質譜檢測分析儀 >
布魯克timsTOF™ Pro捕集離子淌度質譜
布魯克timsTOF™ Pro捕集離子淌度質譜

參考價格

面議

型號

品牌

產地

德國

樣本

暫無
布魯克·道爾頓(Bruker Daltonics)

會員

|

第2年

|

生產商

工商已核實

留言詢價
核心參數
產品介紹
創新點
相關方案
相關資料
用戶評論
公司動態
問商家
留言詢價
×

*留言類型

*留言內容

*聯系人

*單位名稱

*電子郵箱

*手機號

提交
點擊提交代表您同意 《用戶服務協議》《隱私協議》

虛擬號將在 180 秒后失效

使用微信掃碼撥號

為了保證隱私安全,平臺已啟用虛擬電話,請放心撥打(暫不支持短信)
×
是否已溝通完成
您還可以選擇留下聯系電話,等待商家與您聯系

需求描述

單位名稱

聯系人

聯系電話

Email

已與商家取得聯系
同意發送給商家
產品介紹
創新點
相關方案
相關資料
用戶評論
公司動態
問商家

the timsTOF™ Pro Mass Spectrometer Enables the Revolutionary PASEF Method for Next-Generation Proteomics

Unique Trapped Ion Mobility Spectrometry (TIMS) Adds New Dimension for Robust, Faster Proteome Analysis with Higher Sensitivity

Overview

  • Powered by PASEF

Mass spectrometry (MS)-based proteomics has become a powerful technology for the identification and quantification of thousands of proteins. However, the coverage of complete proteomes is still very challenging due to the limited speed, sensitivity and resolution of current mass spectrometers.

The timsTOF Pro uses the Parallel Accumulation Serial Fragmentation (PASEF) acquisition method to provide extremely high speed and sensitivity to reach new depths in shotgun proteomics and phosphoproteomics using low sample amounts.

  • Achieve near 100% duty cycle for shotgun proteomics

A near 100% duty cycle for high sensitivity, high speed shotgun proteomics can now be achieved with the dual TIMS technology. The novel design allows for ions to be accumulated in the front section, while ions in the rear section are simultaneously released depending on their ion mobility. This process is called Parallel Accumulation Serial Fragmentation or PASEF.

  • PASEF digs deeper into the proteome

The timsTOF Pro powered by PASEF offers sequencing speed > 100 Hz without losing sensitivity by synchronizing the quadrupole isolation mass window with the elution time of the specific peptide packages from the TIMS funnel.

  • MaxQuant/Perseus and PEAKS Studio enabled data processing

An open-file data format allows researchers to directly work with the raw data and use industry leading software. MaxQuant has been adapted to manage 4D features in the space spanned by retention time, ion mobility, mass, and signal intensity which benefit the identification and quantification of peptides, proteins, and posttranslational modifications. PEAKS Studio combines de novo sequencingwith tradtional databbase searches and is optimized for processing timsTOF raw data.

Technical Details

  • Outstanding hardware performance

The second generation dual TIMS analyzer is optimized for shotgun proteomics needs. Due to its unique geometry ions are released dependent on their mobility from the second section of the TIMS analyzer while the further incoming ions can be accumulated in parallel in the first part of the TIMS analyzer. With the parallel accumulation technology a duty cycle up to 100% can be achieved resulting in no ion loss.

In the timsTOF Pro an advanced segmented quadrupole mass filter is used for high ion transmission and isolation efficiency. The quadrupole mass position is synchronized with the elution times of the specific ions from the TIMS analyzer. Due to its ultra-high mass position switching time (< 1 ms) it enables the best performance for the PASEF method.

  • TIMS

Trapped Ion Mobility Spectrometry (TIMS) is first and foremost a separation technique in gas phase, which resolves sample complexity with an added dimension of separation in addition to HPLC and mass spectrometry, increasing peak capacity and confidence in compound characterization.

  • PASEF

With speed in mind, Bruker experts redesigned MS/MS technology to meet the requirements of shotgun proteomics. Peptide ions are separated using trapped ion mobility spectrometry, eluted (~ 100 ms) and detected in the QTOF, generating the TIMS MS heat map (A). In the PASEF method (B) the same TIMS separation is used with the quadrupole isolating a certain ion species during its elution and immediately shifting to the next precursor. Parent and fragment spectra are aligned by mobility values. With the Parallel Accumulation Serial Fragmentation (PASEF) Technology >100 Hz sequencing speed can be achieved. With the PASEF method the MS/MS spectra quality of the low abundant peptides can be increased by selecting them several times.

創新點

暫無數據!

相關方案
暫無相關方案。
相關資料
暫無數據。
用戶評論

產品質量

10分

售后服務

10分

易用性

10分

性價比

10分
評論內容
暫無評論!
公司動態
暫無數據!
技術文章
暫無數據!
問商家
  • 布魯克timsTOF™ Pro捕集離子淌度質譜的工作原理介紹?
  • 布魯克timsTOF™ Pro捕集離子淌度質譜的使用方法?
  • 布魯克timsTOF™ Pro捕集離子淌度質譜多少錢一臺?
  • 布魯克timsTOF™ Pro捕集離子淌度質譜使用的注意事項
  • 布魯克timsTOF™ Pro捕集離子淌度質譜的說明書有嗎?
  • 布魯克timsTOF™ Pro捕集離子淌度質譜的操作規程有嗎?
  • 布魯克timsTOF™ Pro捕集離子淌度質譜的報價含票含運費嗎?
  • 布魯克timsTOF™ Pro捕集離子淌度質譜有現貨嗎?
  • 布魯克timsTOF™ Pro捕集離子淌度質譜包安裝嗎?
布魯克timsTOF™ Pro捕集離子淌度質譜信息由布魯克·道爾頓(Bruker Daltonics)為您提供,如您想了解更多關于布魯克timsTOF™ Pro捕集離子淌度質譜報價、型號、參數等信息,歡迎來電或留言咨詢。
  • 推薦分類
  • 同類產品
  • 該廠商產品
  • 相關廠商
  • 推薦品牌
免費
咨詢
手機站
二維碼

主站蜘蛛池模板: 海兴县| 和顺县| 龙江县| 彩票| 泰安市| 闵行区| 壶关县| 北宁市| 陇西县| 宁都县| 三河市| 丹巴县| 宁国市| 余庆县| 汉寿县| 双桥区| 饶阳县| 武清区| 江都市| 汉沽区| 石阡县| 樟树市| 吉木乃县| 白朗县| 嘉善县| 兴安盟| 临江市| 丹棱县| 肇州县| 浙江省| 高州市| 遂宁市| 阆中市| 银川市| 谢通门县| 育儿| 武功县| 渝北区| 栾川县| 余干县| 建阳市|